Oil burners

Home

Serie HB

Type Model Output Mains supply Oil rate of flow Power consumption Weight
2110 HB 21 10-21 kW 230 V / 50Hz 0,9-1,8 kg/h 185 W 13,7 kg
2112 HB 40.1 20-27 kW 230 V / 50Hz 1,7-2,3 kg/h 185 W 13,7 kg
2111 HB 40.2 26-35 kW 230 V / 50Hz 1,7-3,4 kg/h 185 W 13,7 kg
2114 HB 50 37-52 kW 230 V / 50Hz 3,1-4,1 kg/h 360 W 13,7 kg
2115 HB 70 49-70 kW 230 V / 50Hz 4,2-5,9 kg/h 360 W 13,7 kg

Series HB

HB blue burner series are prime examples for highly efficient and environmental friendly combustion. A new oil gasification system provides for absolute blue flame combustion.
Excellent and reliable start performance.
Little wear of ignition electrodes.
Adjustment also possible while in operation.
Particularly energy saving two-step version and exceptional silent operation. Of course tested according DIN EN standard 15034 for air-independent operation and conform to CE-EN 267.


Top of page

Series 5

Type Model Output Mains supply Oil rate of flow Power consumption Weight
8701 HVS 5.3 K 12-43 kW 230 V / 50Hz 1,3-3,5 kg/h 160 W 11,9 kg
8251 HVS 5.3 13-42 kW 230 V / 50Hz 1,3-3,5 kg/h 160 W 12,0 kg
8255 HVS 5.3 G1 25-40 kW 230 V / 50Hz 2,0 3,3 kg/h 160 W 12,0 kg
8254 HVS 5.3 G2 40-60 kW 230 V / 50Hz 3,3-5,0 kg/h 160 W 12,0 kg
8253 HVS 5.3 Ö 19-40 kW 230 V / 50Hz 1,5-3,3 kg/h 160 W 11,9 kg

Series 5

The oil burner of series 5 stands out for absolute quiet run and non–polluting combustion.

They are inspected and authorized in accordance to EN 267 resp. the 1.BImSchV , fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C).

An uniform fuel temperature and optimal atomization are ensured with a build–in oil nozzle preheation system. An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan. Suction and pressure side air–regulation enable a precise air amount adjustment, even at lower capacity ranges, and a simple but accurate adjustment of the fuel–to–air mixture ratio is ensured by a precision mix–equipment.

Furthermore the series impresses by an easy handling, among others with a patent fast lock system, the practical maintanance positions and the variable fitting depth by a standard sliding–flange.

Special editions/models for additional expenses
(Article NR.: 2310) Warm air unit (WLE)


Top of page

Series LN

Type Model Output Mains supply Oil rate of flow Power consumption Weight
1951 HVS 5 LN 1 18–26 kW 230 V/50 Hz 1,6–2,2 kg/h ca. 200 W 12,0 kg
2301 HVS 5 LN 2 26–44 kW 230 V/50 Hz 2,2–3,7 kg/h ca. 200 W 12,0 kg

Series LN

The oil burner of series LN LowNox stands out for absolute quiet run and non–polluting combustion.

They are inspected and authorized in accordance to EN 267, the 1.BImSchV, EMPA, Blue Angel and Land Steiermark GZ 312 H 26/1, fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C).

A uniform fuel temperature and optimal atomization are ensured with a build–in oil nozzle preheation system (DropStop, self-contained of the nozzle) A LowNox precision mix–equipment ensures a non–polluting combustion and guarantees a simple but accurate adjustment of the fuel–to–air mixture ratio. An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is also guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan.

Suction and pressure side air–regulation enable a precise air amount adjustment, even at lower capacity ranges. Furthermore the series impresses by an easy handling, among others with a patent fast lock system, the practical maintanance positions and the variable fitting depth by a standard sliding–flange.

Special editions/Models for additional expenses
(Article NR.: 2310) Warm air unit (WLE)


Top of page

Series HM

Type Model Output Mains supply Oil rate of flow Power consumption Weight
8703 HM 15-44 kW 230 V / 50Hz 1,1-3,7 kg/h 160 W
8704 HMV 15-44 kW 230 V / 50Hz 1,1-3,7 kg/h 160 W

Series HM

The oil burner of series HM stands out for absolute quiet run and non–polluting combustion.

They are inspected and authorized in accordance to EN 267 resp. the 1.BImSchV, fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C).

An uniform fuel temperature and optimal atomization are ensured with a build–in oil nozzle preheation system. An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan. The burner is small.

Special editions/Models for additional expenses
(Article NR.: 2310) Warm air unit (WLE)


Top of page

Series HBG

Type Model Output Mains supply Oil rate of flow Power consumption Weight
2121 HBG 61 15-40 kW 230 V / 50Hz 3,5-6,0 kW 240 W
2120 HBG 62 40-100 kW 230 V / 50Hz 3,5-9,2 kg/h 250 W

Top of page

Series 18

Type Model Output Mains supply Oil rate of flow Power consumption Weight
1217Z HS 18.1 Z 100–168 kW 230 V/50 Hz 8,4–13,5 kg/h ca. 180 W 15,9 kg
1203Z HS 18.2 Z 120–240 kW 230 V/50 Hz 8,4–20,1 kg/h ca. 180 W 15,9 kg

Series 18

The oil burner of series HS 18 stands out for absolute quiet run and non–polluting combustion.

They are inspected and authorized in accordance to EN 267 resp. fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C). (The high/low technology enables a variable operation.) An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan. The pressure side air–regulation enable a precise air amount adjustment, even at lower capacity ranges, and a simple but accurate adjustment of the fuel–to–air mixture ratio is ensured by a precision mix–equipment.

Furthermore the series impresses by an easy handling, among with the practical main–tanance positions and the variable fitting depth by a standard sliding–flange.

Special editions/Models for additional expenses
(Article NR.: 2310) Warm air unit (WLE)
(Article NR.: 3165) Modulation kit (MOD)


Top of page

Series 20/30

Type Model Output Mains supply Oil rate of flow Power consumption Weight
1901 HS 20 Z 137-297 kW 230 V / 50Hz 11,5-24,4 kg/h 360 W 20,5 kg
8705 HS 30 Z 210-370 kW 230 V / 50Hz 17,6-31,2 kg/h 360 W 21,0 kg

Series 20/30

The oil burner of series 20 stands out for absolute quiet run and non–polluting combustion.

They are inspected and authorized in accordance to EN 267, fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C).

The high/low technology enables a variable operation. An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan. Suction and pressure side air–regulation enable a precise air amount adjustment, even at lower capacity ranges, and a simple but accurate adjustment of the fuel–to–air mixture ratio is ensured by a precision mix–equipment.

Furthermore the series impresses by an easy handling, among others with the practical maintanance positions and the variable fitting depth by a standard sliding–flange.

Special editions/Models for additional expenses
(Article NR.: 2310) Warm air unit (WLE)
(Article NR.: 3166) Modulation kit (MOD)


Top of page

Series 50/70

Type Model Output Mains supply Oil rate of flow Power consumption Weight
2201 HS 50 Z 198-480 kW 230 V / 50Hz 16,7-40,5 kg/h 700 W 36,1 kg
2601 HS 50 ZL 198-480 kW 230 V / 50Hz 16,7-40,5 kg/h 700 W 36,4 kg
2851 HS 70 Z 360-711 kW 230 V / 50Hz 30,3-60,0 kg/h 1400 W 38,0 kg
2852 HS 70 ZL 360-711 kW 230 V / 50Hz 30,3-60,0 kg/h 1400 W 38,3 kg

Series 50/70

The oil burner of series 50/70 stands out for absolute quiet run and non–polluting combustion.

They are inspected and authorized in accordance to EN 267, fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C).

The high/low technology enables a variable operation. An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan.

Suction and pressure side air-regulation enable a precise air amount adjustment, even at lower capacity ranges, and a simple but accurate adjustment of the fuel-to-air mixture ratio is ensured by a precision mix–equipment.

Furthermore the series impresses by an easy handling, among others the practical maintanance positions and the variable fitting depth by a standard sliding–flange.


Top of page

Series 100/200

Type Model Output Mains supply Oil rate of flow Power consumption Weight
2856 HS 100 Z 320-1008 kW 230 V / 50 Hz 27,0-85,0 kg/h 54.0 kg
2857 Hs 200 Z 593-2182 kW 230 V / 50 Hz 50,0-184,0 kg/h 97.0 kg

Series 100/200

The oil burner of series HS 100Z stands out for absolute quiet run and non-polluting combustion.

They are inspected and authorized in accordance to EN 267 resp. fitted for combustion of extra light oil according to DIN 51603 with max. 6,0cSt/293K (20°C).

The high/low technology enables a variable operation. An air choke prevents a fast cooling out of the combustion chamber during non operation of the apparatus. There is guaranteed a safe starting–up as well as a stable combustion by an optimised high–pressure fan.

The pressure side air-regulation enable a precise air amount adjustment, even at lower capacity ranges, and a simple but accurate adjustment of the fuel–to–air mixture ratio is ensured by a precision mix–equipment.


Top of page